Calibration Station for the GX-3R
$1,785.00Stand Alone Use
The SDM-3R is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).PC-Controlled Use
Automate how you manage and service GX-3R (Pro) instruments by connecting the SDM-3R to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, alarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from each instrument into one easy to manage location. SDM-3R stations can be manifolded together to reduce the number of demand flow regulators gas cylinders required.Specifications
Input Power AC Adapter with 100 – 240 VAC, 47-63 Hz, 0.4A input and 5.99 VDC, 2A output provided as standard. Environmental Conditions For Indoor Use Only 0° C to 40° C, below 95% Relative Humidity, Non-Condensing
Applicable Instruments GX-3R and GX-3R Pro Maximum Number of Records Saved
Stand Alone: 200 calibrations, or 214 bump test, or 469 alarm check records
PC program Controlled: Unlimited records5 Ports 3 Calibration gas, 1 fresh air and 1 exhaust Standard Accessories - AC Adapter
- USB Flash Drive
- Inlet Air Filter
- 10 Foot Long Exhaust Tube
- One 3 Foot Long Tube for GAS Fitting
- USB Cable, Type A to Type B
Specifications subject to change without notice.
-
GX-2012 5 Sensor LI-lon battery pack
$1,307.00With the GX-2012, you have multiple tools in one instrument. Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in it’s Normal Operating mode; for leak investigation in Leak Check mode; and for underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto range from % LEL to % volume. This is ideal for line purge testing.
Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide).
The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.
-
GX-2012 5 Sensor LI-lon batterypack
$1,315.00With the GX-2012, you have multiple tools in one instrument. Having 3 operating modes, the GX-2012 can be used for confined space, safety monitoring in it’s Normal Operating mode; for leak investigation in Leak Check mode; and for underground leak checking in Bar Hole mode. When equipped with an optional TC sensor, the GX-2012 can measure 100% volume methane and dynamically auto range from % LEL to % volume. This is ideal for line purge testing.
Built around high-quality micro-sensor technology, the GX-2012 is RKI’s smallest personal 1-5 sensor gas monitor with a built in sample pump. Weighing only 12.3 ounces, the GX-2012 can monitor the standard confined space gases (LEL combustibles, Oxygen content, Carbon Monoxide, and Hydrogen Sulfide).
The GX-2012’s large LCD display shows all gas readings, battery level, current time, and will automatically backlight in alarm conditions. Standard alarm types include vibration, visual, and audible alarms, which can be set to latching or non-latching. Controlled by a microprocessor, the GX-2012 continuously checks itself for sensor connections, low battery, circuit trouble, low flow, and calibration errors. The GX-2012 can interchangeably operate on either a Li-ion battery pack or an alkaline battery pack. The batteries are simple to replace requiring no tools to access the removable battery compartment or pack.
Gas Detected Combustible Gases
(Methane as standard)% Volume
MethaneOxygen (O2) Hydrogen Sulfide (H2S) Carbon Monoxide (CO) Detection Principle Catalytic combustion Thermal conductivity Galvanic cell Electrochemical cell Detection Range 0 ~ 100% LEL
0 ~ 500 / 1,000 / 2,000 / 5,000 ppm0 ~ 100% Vol. 0 ~ 40% Vol. 0 ~ 100 ppm
(optional 0-500 ppm)0 ~ 500 ppm Accuracy Statement
(whichever is greater)± 5% of reading or
± 2% LEL(LEL mode only)± 5% of reading or ± 2% of full scale ± 0.5% O2 ± 5% of reading or ± 2 ppm H2S ± 5% of reading or ± 5 ppm CO Sampling Method Internal sample pump, flow rate nominal 0.5 LPM, includes hydrophobic filter Display Digital LCD with 7 segments, auto backlight during alarm Preset Alarms
(User Adjustable)1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LELNo alarms for
% Vol. CH4Low alarm 19.5% High alarm 23.5% Over alarm 40.0% 1st 5 ppm
2nd 30 ppm
TWA 10 ppm
STEL 15 ppm
Over 100 ppm1st 25 ppm
2nd 50 ppm
TWA 25 ppm
STEL 200 ppm
Over 500 ppmAlarms Types Gas alarms: 1st and 2nd, STEL, TWA (user adjustable) and OVER
Trouble alarms: Sensor connection, low battery, low flow, circuit trouble and calibration errorAlarm Methods Gas alarms: Flashing lights, two tone buzzer, and vibration
Trouble alarms: Flashing lights, trouble displayed, intermittent buzzer, and vibrationOperating Temp. & Humidity -20°C to +50°C (-4°F to 122°F)
0 to 95% RH, non-condensingResponse Time Within 30 seconds (T90) Continuous Operation Alkaline battery: 15 hours Li-Ion battery: 10 hours
70°F (21°C)Power Source Li-Ion battery pack, or 3 “AA” Alkaline battery pack; interchangeable Safety Rating ATEX, TIIS, IECEx, CE, CSA classified (as standard), as intrinsically safe. Class I, Division 1, Groups A, B, C, D (optional version available) Dimension & Weight Approx. 143 (H) x 71 (W) x 43 (D) mm (5.6” H x 2.8” W x 1.6” D), approx. 350 g (12.3 ounces) Case Material High dust & water resistant design. RFI shielded high impact plastic with protective rubber overmolding Controls Five buttons: POWER / ENTER, DISPLAY, AIR, RESET, SHIFT Standard Accessories - •Belt clip
- Rubber nozzle, 3.5”
- Datalogging software
- 10” Probe
- Manual
- Quick reference card
- 10’ Hose
- Training CD
Optional Accessories - SDM-2012 calibration stations
- Calibration kit
- Li-Ion battery pack
- AC or DC Charger
- Sample draw hoses (10’ standard, up to 100’ max. available)
- Carrying case